{"id":894,"date":"2016-08-06T06:24:08","date_gmt":"2016-08-06T06:24:08","guid":{"rendered":"http:\/\/www.hotoilboiler.com\/pt-pt\/?p=894"},"modified":"2022-06-02T02:34:53","modified_gmt":"2022-06-02T02:34:53","slug":"12kw-heating-eletrico-quente-caldeiras-a-oleo","status":"publish","type":"post","link":"https:\/\/www.hotoilboiler.com\/pt-pt\/12kw-heating-eletrico-quente-caldeiras-a-oleo\/","title":{"rendered":"12kW Heating el\u00e9trico quente Caldeiras a \u00f3leo"},"content":{"rendered":"<p><a href=\"https:\/\/www.hotoilboiler.com\/wp-content\/uploads\/2015\/05\/Electric-Heating-Hot-Oil-Boilers-Thermal-Oil-Heaters.jpg\"><img decoding=\"async\" class=\"alignnone size-full wp-image-273\" src=\"https:\/\/www.hotoilboiler.com\/wp-content\/uploads\/2015\/05\/Electric-Heating-Hot-Oil-Boilers-Thermal-Oil-Heaters.jpg\" alt=\"Electric-Heating-Hot-Oil-Boilers-Thermal-Oil-Heaters\" width=\"1000\" height=\"587\" \/><\/a><\/p>\n<p>caldeira de \u00f3leo quente aquecimento el\u00e9ctrico (tamb\u00e9m conhecido como aquecedor de \u00f3leo de condu\u00e7\u00e3o de calor), o aquecedor el\u00e9trico est\u00e1 diretamente inserida no \u00f3leo t\u00e9rmico (\u00f3leo de condu\u00e7\u00e3o de calor) para o aquecimento direto. Uma bomba de circula\u00e7\u00e3o \u00e9 utilizado para criar a circula\u00e7\u00e3o da fase l\u00edquida de \u00f3leo de condu\u00e7\u00e3o de calor, assim, para transferir o calor de uma ou v\u00e1rias pe\u00e7as de equipamento que utilizam calor. Depois de descarregado no calor usando equipamento, o \u00f3leo de condu\u00e7\u00e3o de calor vai retornar para o aquecedor atrav\u00e9s da bomba de circula\u00e7\u00e3o, de novo para absorver o calor, e transferir o calor para o calor usando equipamento. Este processo \u00e9 repetido uma e outra vez, percebendo transfer\u00eancia cont\u00ednua de calor. Como resultado, a temperatura dos objectos a ser aquecido aumenta, e as necessidades de aquecimento sejam cumpridas.<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_80 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<label for=\"ez-toc-cssicon-toggle-item-69ea9b137ac43\" class=\"ez-toc-cssicon-toggle-label\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/label><input type=\"checkbox\"  id=\"ez-toc-cssicon-toggle-item-69ea9b137ac43\"  aria-label=\"Toggle\" \/><nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.hotoilboiler.com\/pt-pt\/12kw-heating-eletrico-quente-caldeiras-a-oleo\/#Aplicacao_de_Heating_eletrico_quente_Caldeiras_a_oleo\" >Aplica\u00e7\u00e3o de Heating el\u00e9trico quente Caldeiras a \u00f3leo<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.hotoilboiler.com\/pt-pt\/12kw-heating-eletrico-quente-caldeiras-a-oleo\/#Caracteristica_do_Heating_eletrico_quente_Caldeiras_a_oleo\" >Caracter\u00edstica do Heating el\u00e9trico quente Caldeiras a \u00f3leo<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.hotoilboiler.com\/pt-pt\/12kw-heating-eletrico-quente-caldeiras-a-oleo\/#System_Drawing_of_Electric_Heating_Thermal_Oil_Heaters\" >System Drawing of Electric Heating Thermal Oil Heaters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.hotoilboiler.com\/pt-pt\/12kw-heating-eletrico-quente-caldeiras-a-oleo\/#Constituent_Part_of_Electric_Heating_Thermal_Oil_Boilers\" >Constituent Part of Electric Heating Thermal Oil Boilers<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.hotoilboiler.com\/pt-pt\/12kw-heating-eletrico-quente-caldeiras-a-oleo\/#Parameter_Table_of_Electric_Heating_Thermal_Oil_Heaters\" >Parameter Table of Electric Heating Thermal Oil Heaters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.hotoilboiler.com\/pt-pt\/12kw-heating-eletrico-quente-caldeiras-a-oleo\/#Company_Profile\" >Company Profile<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.hotoilboiler.com\/pt-pt\/12kw-heating-eletrico-quente-caldeiras-a-oleo\/#Send_Us_Inquiry_to_Get_Quotation\" >Send Us Inquiry to Get Quotation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.hotoilboiler.com\/pt-pt\/12kw-heating-eletrico-quente-caldeiras-a-oleo\/#Send_Us_Inquiry_to_Get_Quotation-2\" >Send Us Inquiry to Get Quotation<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Aplicacao_de_Heating_eletrico_quente_Caldeiras_a_oleo\"><\/span>Aplica\u00e7\u00e3o de Heating el\u00e9trico quente Caldeiras a \u00f3leo<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Controle el\u00e9trico de aquecimento quente caldeira de \u00f3leo de temperatura por attemperation digital de exibi\u00e7\u00e3o, com alarme de super temperatura, alarme de baixo n\u00edvel de \u00f3leo, as fun\u00e7\u00f5es de super alarme de press\u00e3o, e \u00e9 amplamente utilizado na ind\u00fastria qu\u00edmica, petr\u00f3leo, m\u00e1quinas, impress\u00e3o e tingimento, t\u00eaxtil, alimentar, os navios , as ind\u00fastrias de cinema. \u00c9 uma esp\u00e9cie de alta energia do equipamento de aquecimento efici\u00eancia.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-271\" src=\"https:\/\/www.hotoilboiler.com\/wp-content\/uploads\/2015\/05\/Thermal-Oil-Heater-Expansion-Tank.jpg\" alt=\"Thermal-Oil-Heater-Expansion-Tank\" width=\"1000\" height=\"552\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Caracteristica_do_Heating_eletrico_quente_Caldeiras_a_oleo\"><\/span>Caracter\u00edstica do Heating el\u00e9trico quente Caldeiras a \u00f3leo<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>1. press\u00e3o de trabalho Baixo<br \/>\nenergia de calor de transporte em fase l\u00edquida, pode sob baixa press\u00e3o de trabalho e obter alta temperatura, portador de calor \u00e9 menor do que a press\u00e3o do vapor de satura\u00e7\u00e3o da \u00e1gua 70 ~ 80 vezes, o aquecimento geral por menos de 0,3 MPa.<br \/>\n2. Alta temperatura de aquecimento<br \/>\ncondu\u00e7\u00e3o de calor forno de aquecimento de \u00f3leo pode atingir a temperatura de 280 \u2103 .A temperatura de aquecimento de controlo autom\u00e1tico, de alta sensibilidade, a estabilidade de aquecimento.<br \/>\n3. Seguro e confi\u00e1vel<br \/>\nforno de \u00f3leo de condu\u00e7\u00e3o de calor \u00e9 equipado com controle perfeito funcionamento e dispositivo de monitoramento de seguran\u00e7a, facilidade de opera\u00e7\u00e3o, seguran\u00e7a e confiabilidade.<br \/>\n4. O projeto de prote\u00e7\u00e3o ambiental<br \/>\ncaldeira de \u00f3leo quente aquecimento el\u00e9ctrico \u00e9 fornecido com o novo sistema de aquecimento el\u00e9trico, usando el\u00e9trica em vez de carv\u00e3o, poupando investimentos, ambiental e nenhuma polui\u00e7\u00e3o, e forno de \u00f3leo de condu\u00e7\u00e3o de calor aquecendo r\u00e1pido, de alta eficiente e mais econ\u00f4mico.<\/p>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"System_Drawing_of_Electric_Heating_Thermal_Oil_Heaters\"><\/span>System Drawing of Electric Heating Thermal Oil Heaters<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><a href=\"https:\/\/www.hotoilboiler.com\/wp-content\/uploads\/2015\/05\/Electric-Heating-Thermal-Oil-Heaters-Working-Flow.jpg\"><img decoding=\"async\" class=\"alignnone size-full wp-image-461\" src=\"https:\/\/www.hotoilboiler.com\/wp-content\/uploads\/2015\/05\/Electric-Heating-Thermal-Oil-Heaters-Working-Flow.jpg\" alt=\"Electric-Heating-Thermal-Oil-Heaters-Working-Flow\" width=\"1000\" height=\"688\" \/><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Constituent_Part_of_Electric_Heating_Thermal_Oil_Boilers\"><\/span>Constituent Part of Electric Heating Thermal Oil Boilers<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>\uff081\uff09\u00a0\u00a0 \u00a0Shell\uff1a<br \/>\nHousing material\uff1acarbon steel\uff1b<br \/>\nInner drum size\uff1a\u03a6159\u00d71200mm<br \/>\nHeat preservation material\uff1aaluminum silicate wool\uff1b<br \/>\nThermal insulation layer thickness\uff1a120mm\uff1b<br \/>\nConnection caliber\uff1aDN32\uff1b<br \/>\n\uff082\uff09\u00a0\u00a0 \u00a0Heating structure\uff1a<br \/>\nHeating tube material: stainless steel 304\uff1b<br \/>\nTotal power\uff1a12 KW\uff1b<br \/>\nVoltage\uff1a380 V\uff1b<br \/>\n\uff083\uff09Hot oil pump\uff1a<br \/>\nMotor power\uff1a1.5KW\uff1b<br \/>\nPump flow\uff1a6m3\/h\uff1b<br \/>\nDelivery lift\uff1a28m\uff1b<br \/>\n\uff084\uff09Expansion slot\uff1a<br \/>\nSize\uff1a\u03a6300\u00d7400mm\uff1b<br \/>\nMaterial\uff1acarbon steel\uff1b<br \/>\n\uff085\uff09Control system\uff1a<br \/>\nIncluding body\uff0cXMT temperature control meter\uff0cfast melting\uff0cthermocouples\uff0cair switch\uff0c<br \/>\nsolid-state relay\uff0celectric heating table\uff0c voltmeter\uff0c etc\uff1b<br \/>\n\uff086\uff09Accessories:<br \/>\nlevel gauge, cut-off valve, pressure gauge, filter, the exhaust valve, drain valve, etc.<br \/>\nPlease note\uff1aElectric heating hot oil boiler with the function of pressure interlock alarming\uff0cliquid level interlock alarming\uff0cthe heater temperature alarm and pump interlocking<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Parameter_Table_of_Electric_Heating_Thermal_Oil_Heaters\"><\/span>Parameter Table of Electric Heating Thermal Oil Heaters<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<table width=\"837\">\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"219\">Model<\/td>\n<td width=\"103\">YDW-9KW<\/td>\n<td width=\"103\">YDW-30KW<\/td>\n<td width=\"103\">YDW-48KW<\/td>\n<td width=\"103\">YDW-60KW<\/td>\n<td width=\"103\">YDW-72KW<\/td>\n<td width=\"103\">YDW-90KW<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"142\">Rated Power<\/td>\n<td width=\"77\">KW<\/td>\n<td width=\"103\">9<\/td>\n<td width=\"103\">30<\/td>\n<td width=\"103\">48<\/td>\n<td width=\"103\">60<\/td>\n<td width=\"103\">72<\/td>\n<td width=\"103\">90<\/td>\n<\/tr>\n<tr>\n<td width=\"77\">10<sup>4<\/sup>kcal<\/td>\n<td width=\"103\">0.8<\/td>\n<td width=\"103\">2.5<\/td>\n<td width=\"103\">4<\/td>\n<td width=\"103\">5<\/td>\n<td width=\"103\">6<\/td>\n<td width=\"103\">8<\/td>\n<\/tr>\n<tr>\n<td width=\"142\">Thermal Efficiency<\/td>\n<td width=\"77\">%<\/td>\n<td colspan=\"6\" width=\"618\">97<\/td>\n<\/tr>\n<tr>\n<td width=\"142\">Design Pressure<\/td>\n<td width=\"77\">mpa<\/td>\n<td colspan=\"6\" width=\"618\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"142\">Max Temperature<\/td>\n<td width=\"77\">\u2103<\/td>\n<td colspan=\"6\" width=\"618\">300<\/td>\n<\/tr>\n<tr>\n<td width=\"142\">Thermal Oil Volume<\/td>\n<td width=\"77\">m\u00b3\/h<\/td>\n<td width=\"103\">0.006<\/td>\n<td width=\"103\">0.025<\/td>\n<td width=\"103\">0.025<\/td>\n<td width=\"103\">0.05<\/td>\n<td width=\"103\">0.11<\/td>\n<td width=\"103\">0.08<\/td>\n<\/tr>\n<tr>\n<td width=\"142\">Connection Diameter<\/td>\n<td width=\"77\"><\/td>\n<td width=\"103\">25<\/td>\n<td width=\"103\">50<\/td>\n<td width=\"103\">50<\/td>\n<td width=\"103\">50<\/td>\n<td width=\"103\">50<\/td>\n<td width=\"103\">50<\/td>\n<\/tr>\n<tr>\n<td width=\"142\">Power Consumption<\/td>\n<td width=\"77\">KW<\/td>\n<td width=\"103\">10.5<\/td>\n<td width=\"103\">33<\/td>\n<td width=\"103\">51<\/td>\n<td width=\"103\">63<\/td>\n<td width=\"103\">75<\/td>\n<td width=\"103\">95.5<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"142\">Dimension<\/td>\n<td width=\"77\">L mm<\/td>\n<td width=\"103\">1460<\/td>\n<td width=\"103\">1600<\/td>\n<td width=\"103\">2200<\/td>\n<td width=\"103\">1900<\/td>\n<td width=\"103\">2000<\/td>\n<td width=\"103\">1780<\/td>\n<\/tr>\n<tr>\n<td width=\"77\">W mm<\/td>\n<td width=\"103\">550<\/td>\n<td width=\"103\">710<\/td>\n<td width=\"103\">1100<\/td>\n<td width=\"103\">1100<\/td>\n<td width=\"103\">1700<\/td>\n<td width=\"103\">485<\/td>\n<\/tr>\n<tr>\n<td width=\"77\">H mm<\/td>\n<td width=\"103\">405<\/td>\n<td width=\"103\">1384<\/td>\n<td width=\"103\">1550<\/td>\n<td width=\"103\">1576<\/td>\n<td width=\"103\">2000<\/td>\n<td width=\"103\">2215<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"219\">Weight<\/td>\n<td width=\"103\">155<\/td>\n<td width=\"103\">580<\/td>\n<td width=\"103\">680<\/td>\n<td width=\"103\">720<\/td>\n<td width=\"103\">800<\/td>\n<td width=\"103\">950<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table width=\"837\">\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"219\">Model<\/td>\n<td width=\"103\">YDW-120KW<\/td>\n<td width=\"103\">YDW-160KW<\/td>\n<td width=\"103\">YDW-240KW<\/td>\n<td width=\"103\">YDW-360KW<\/td>\n<td width=\"103\">YDW-480KW<\/td>\n<td width=\"103\">YDW-600KW<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"142\">Rated Power<\/td>\n<td width=\"77\">KW<\/td>\n<td width=\"103\">120<\/td>\n<td width=\"103\">160<\/td>\n<td width=\"103\">240<\/td>\n<td width=\"103\">360<\/td>\n<td width=\"103\">480<\/td>\n<td width=\"103\">600<\/td>\n<\/tr>\n<tr>\n<td width=\"77\">10<sup>4<\/sup>kcal<\/td>\n<td width=\"103\">10<\/td>\n<td width=\"103\">13<\/td>\n<td width=\"103\">20<\/td>\n<td width=\"103\">30<\/td>\n<td width=\"103\">40<\/td>\n<td width=\"103\">50<\/td>\n<\/tr>\n<tr>\n<td width=\"142\">Thermal Efficiency<\/td>\n<td width=\"77\">%<\/td>\n<td colspan=\"6\" width=\"618\">97<\/td>\n<\/tr>\n<tr>\n<td width=\"142\">Design Pressure<\/td>\n<td width=\"77\">mpa<\/td>\n<td colspan=\"6\" width=\"618\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"142\">Max Temperature<\/td>\n<td width=\"77\">\u2103<\/td>\n<td colspan=\"6\" width=\"618\">300<\/td>\n<\/tr>\n<tr>\n<td width=\"142\">Thermal Oil Volume<\/td>\n<td width=\"77\">m\u00b3\/h<\/td>\n<td width=\"103\">0.11<\/td>\n<td width=\"103\">0.11<\/td>\n<td width=\"103\">0.21<\/td>\n<td width=\"103\">0.35<\/td>\n<td width=\"103\">0.4<\/td>\n<td width=\"103\">0.5<\/td>\n<\/tr>\n<tr>\n<td width=\"142\">Connection Diameter<\/td>\n<td width=\"77\"><\/td>\n<td width=\"103\">50<\/td>\n<td width=\"103\">65<\/td>\n<td width=\"103\">65<\/td>\n<td width=\"103\">80<\/td>\n<td width=\"103\">80<\/td>\n<td width=\"103\">100<\/td>\n<\/tr>\n<tr>\n<td width=\"142\">Power Consumption<\/td>\n<td width=\"77\">KW<\/td>\n<td width=\"103\">125.5<\/td>\n<td width=\"103\">167.5<\/td>\n<td width=\"103\">255<\/td>\n<td width=\"103\">376.5<\/td>\n<td width=\"103\">496.5<\/td>\n<td width=\"103\">623.5<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"142\">Dimension<\/td>\n<td width=\"77\">L mm<\/td>\n<td width=\"103\">1780<\/td>\n<td width=\"103\">1780<\/td>\n<td width=\"103\">2150<\/td>\n<td width=\"103\">2150<\/td>\n<td width=\"103\">2650<\/td>\n<td width=\"103\">2150<\/td>\n<\/tr>\n<tr>\n<td width=\"77\">W mm<\/td>\n<td width=\"103\">965<\/td>\n<td width=\"103\">1100<\/td>\n<td width=\"103\">2129<\/td>\n<td width=\"103\">2600<\/td>\n<td width=\"103\">2000<\/td>\n<td width=\"103\">3100<\/td>\n<\/tr>\n<tr>\n<td width=\"77\">H mm<\/td>\n<td width=\"103\">2006<\/td>\n<td width=\"103\">1924<\/td>\n<td width=\"103\">1650<\/td>\n<td width=\"103\">1950<\/td>\n<td width=\"103\">2600<\/td>\n<td width=\"103\">1950<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"219\">Weight<\/td>\n<td width=\"103\">1150<\/td>\n<td width=\"103\">1350<\/td>\n<td width=\"103\">2650<\/td>\n<td width=\"103\">3150<\/td>\n<td width=\"103\">3430<\/td>\n<td width=\"103\">4150<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span class=\"ez-toc-section\" id=\"Company_Profile\"><\/span>Company Profile<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Romiter Group Limited are committed to manufacturing and exporting complete enery saving heating equipment, including thermal oil boiler (Thermal fluid heat transfer product), thermal oil steam generator, cryogenic storage Dewar.\u00a0 After many years reach &amp; development, Romiter Group can provide <a href=\"https:\/\/www.hotoilboiler.com\/4700kw-chain-grate-coal-fired-thermal-oil-boilers\/\">coal fired thermal oil boiler<\/a>, <a href=\"https:\/\/www.hotoilboiler.com\/500kw-natural-gas-fired-thermal-oil-boiler\/\">gas fired thermal oil boiler<\/a>, <a href=\"https:\/\/www.hotoilboiler.com\/yyw-diesel-oil-fired-thermal-oil-boilers\/\">diesel fired thermal oil boiler<\/a>, <a href=\"https:\/\/www.hotoilboiler.com\/5kw-electric-heating-thermal-oil-heaters\/\">electric heating thermal oil boiler,<\/a> <a href=\"https:\/\/www.hotoilboiler.com\/8200kw-coal-fired-molten-salt-heater\/\">coal fired molten salt heater<\/a>, gas or oil fired molten salt heater and all type <a href=\"https:\/\/www.hotoilboiler.com\/cryogenic-storage-dewar\/\">liquid gas vacuum cryogenic storage Dewar.<\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Send_Us_Inquiry_to_Get_Quotation\"><\/span>Send Us Inquiry to Get Quotation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f4-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"4\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/pt-pt\/wp-json\/wp\/v2\/posts\/894#wpcf7-f4-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"4\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.1.4\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f4-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/fieldset>\n<div id=\"inquiryForm\">\n\t<h2><span class=\"ez-toc-section\" id=\"Send_Us_Inquiry_to_Get_Quotation-2\"><\/span>Send Us Inquiry to Get Quotation\n\t<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\t<p>Please enter your contact information and the details you want to know about our product.\n\t<\/p>\n\t<p>Your Name (required)\n\t<\/p>\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span>\n\t<\/p>\n\t<p>Your Email (required)\n\t<\/p>\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span>\n\t<\/p>\n\t<p>Country\n\t<\/p>\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-country\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" placeholder=\"Tell us Your Country\" value=\"\" type=\"text\" name=\"your-country\" \/><\/span>\n\t<\/p>\n\t<p>WhatsApp\n\t<\/p>\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-whatsapp\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" placeholder=\"Your WhatsApp ID with Country Code\" value=\"\" type=\"text\" name=\"your-whatsapp\" \/><\/span>\n\t<\/p>\n\t<p>Subject\n\t<\/p>\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-subject\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"your-subject\" \/><\/span>\n\t<\/p>\n\t<p>Your Message\n\t<\/p>\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" placeholder=\"please specify your detail requirement here\" name=\"your-message\"><\/textarea><\/span>\n\t<\/p>\n\t<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Send\" \/>\n\t<\/p>\n<\/div><p style=\"display: none !important;\" class=\"akismet-fields-container\" data-prefix=\"_wpcf7_ak_\"><label>&#916;<textarea name=\"_wpcf7_ak_hp_textarea\" cols=\"45\" rows=\"8\" maxlength=\"100\"><\/textarea><\/label><input type=\"hidden\" id=\"ak_js_1\" name=\"_wpcf7_ak_js\" value=\"221\"\/><script>document.getElementById( \"ak_js_1\" ).setAttribute( \"value\", ( new Date() ).getTime() );<\/script><\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>caldeira de \u00f3leo quente aquecimento el\u00e9ctrico (tamb\u00e9m conhecido como aquecedor de \u00f3leo de condu\u00e7\u00e3o de calor), o aquecedor el\u00e9trico est\u00e1 diretamente inserida no \u00f3leo t\u00e9rmico (\u00f3leo de condu\u00e7\u00e3o de calor) para o aquecimento direto. Uma bomba de circula\u00e7\u00e3o \u00e9 utilizado para criar a circula\u00e7\u00e3o da fase l\u00edquida de \u00f3leo de condu\u00e7\u00e3o de calor, assim, para transferir o calor de uma ou v\u00e1rias pe\u00e7as de equipamento que utilizam calor. Depois de descarregado no calor usando equipamento, o \u00f3leo de condu\u00e7\u00e3o de calor vai retornar para o aquecedor atrav\u00e9s da bomba de circula\u00e7\u00e3o, de novo para absorver o calor, e transferir o calor para o calor usando equipamento. Este processo \u00e9 repetido uma e outra vez, percebendo transfer\u00eancia cont\u00ednua de calor. Como resultado, a temperatura dos objectos a ser aquecido aumenta, e as necessidades de aquecimento sejam cumpridas. Aplica\u00e7\u00e3o de Heating el\u00e9trico quente Caldeiras a \u00f3leo Controle el\u00e9trico de aquecimento quente caldeira de \u00f3leo de temperatura por attemperation digital de exibi\u00e7\u00e3o, com &#8230;<\/p>\n","protected":false},"author":1,"featured_media":2758,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[331],"tags":[353],"class_list":["post-894","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-aquecimento-electrico-caldeira-de-oleo-termico","tag-12kw-heating-eletrico-quente-caldeiras-a-oleo"],"aioseo_notices":[],"jetpack_featured_media_url":"https:\/\/www.hotoilboiler.com\/wp-content\/uploads\/2015\/05\/Electric-Heating-Hot-Oil-Boilers-Thermal-Oil-Heaters-1.jpg","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hotoilboiler.com\/pt-pt\/wp-json\/wp\/v2\/posts\/894","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hotoilboiler.com\/pt-pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hotoilboiler.com\/pt-pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hotoilboiler.com\/pt-pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hotoilboiler.com\/pt-pt\/wp-json\/wp\/v2\/comments?post=894"}],"version-history":[{"count":0,"href":"https:\/\/www.hotoilboiler.com\/pt-pt\/wp-json\/wp\/v2\/posts\/894\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hotoilboiler.com\/pt-pt\/wp-json\/wp\/v2\/media\/2758"}],"wp:attachment":[{"href":"https:\/\/www.hotoilboiler.com\/pt-pt\/wp-json\/wp\/v2\/media?parent=894"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hotoilboiler.com\/pt-pt\/wp-json\/wp\/v2\/categories?post=894"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hotoilboiler.com\/pt-pt\/wp-json\/wp\/v2\/tags?post=894"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}